Un buen diseño de modernización de la iluminación del aula debe cumplir con estos estándares
For classroom lighting, we must choose the best lighting fixtures from the perspective of illuminance and uniformity. As for the requirements for blackboard lighting, we have all been students. In the past, people who were seated close to the side couldn't see the blackboard. That was because the blackboard light was not installed properly, or even there was no blackboard light, and there were reflections, so the blackboard lighting would also affect the students' eyesight.
Un buen diseño de renovación de la iluminación del aula debe cumplir con los siguientes estándares:
1. Se debe instalar iluminación artificial en las aulas.
2. El valor de iluminancia promedio mantenido en el escritorio del aula no debe ser inferior a 300lx, y la uniformidad de iluminancia no debe ser inferior a 0,7.
3. La pizarra del aula debe estar equipada con iluminación local, la iluminancia promedio no debe ser inferior a 500lx y la uniformidad de la iluminancia no debe ser inferior a 0,8.
4. El salón de clases debe usar una fuente de luz con una temperatura de color de 3300-5500K, y el índice de reproducción cromática de la fuente de luz no debe ser inferior a 80.
5. El valor de deslumbramiento unificado (UGR) del aula no debe ser superior a 19.
6. Under the condition of maintaining the average illuminance value of 300lx, the current value of classroom lighting power density should not be greater than 11W/㎡, and the target value should be 9W/㎡.
7. Al calcular la iluminancia en el diseño de iluminación, su efecto de mantenimiento se toma como 0.8.
Therefore, in order to effectively avoid the impact of educational lighting on students' vision, schools should use professional eye-protecting LED educational lighting fixtures, and professional technicians should be responsible for the installation to ensure the indicators of classroom lights and blackboard lights in educational lighting. All can meet the qualified requirements, ensuring that the light environment of each classroom not only has sufficient illumination and excellent uniformity, but also minimizes glare, so that no direct light enters the eyes of students.
Al mismo tiempo, la ubicación de la iluminación educativa en el salón de clases debe renovarse para evitar la superposición de luces en el salón de clases y la falta de luz de punto ciego, a fin de brindar a los estudiantes un ambiente de iluminación educativo saludable, cómodo y verde.